logo
Welcome Guest! To enable all features please Login or Register.

Notification

Icon
Error

Login


Options
View
Go to last post Go to first unread
swpt_5t59Cboq  
#1 Posted : Thursday, March 18, 2021 5:16:35 AM(UTC)
swpt_5t59Cboq

Rank: Newbie

Groups: Registered
Joined: 3/13/2021(UTC)
Posts: 5

Embedded Host For Data Center Environmental Monitoring?ARM architecture; B/S design; Embedded Linux operating system, no need to install additional servers and software.?1.Product IntroductionThis product is specially designed for modern computer and network communication room, outdoor cabinet and remote multi-functional monitoring host. The management system cooperates with relevant sensors to monitor gate magnetism, power supply and distribution, lighting, generator, UPS, precision air conditioning, fresh air blower, harmful gas, fire control controller, smoke, leakage, infrared, lightning protection, vibration/tilt, air switch tripping and other alarms. Once the relevant parameters of the computer room are abnormal, the management system will inform the relevant managers at the first time through short message, telephone, mail, sound and light alarm, so as to ensure that the failure of the equipment in the computer room can be detected and solved in time. At the same time, the flexible output control device can freely set the linkage output of any fault.2.Product Parameter (specification)? ? ?ITEMMODELDESCRIPTIONINPUTDIGITAL INPUT16 DIGITAL INPUT,?? ? ?Built-in DC12V power supply, MAX current:?1.5ALEAK SENSOR1 LEAK SENSOR INPUTOUTPUTDIGITAL OUTPUT2 RELAY(AC250V/3AOR DC30V/3A)PORTSERIAL PORT4?RS232:1200~115200bps default?96004?RS485:?1200~19200bps default?9600Built-in DC12V power supply, MAX current:?1AETHERNET2 10/100/1000MPOWER SUPLIERINPUTAC100~240VWATT72WREDUNDANTDUAL POWER SUPPLY REDUNDANT INPUTSWITCH TIME<10msENVIRONME NTTEMP-20℃~70℃HUMI5%RH~95%RHOTHERHOST SIZE439mm*216mm*45mmN.W3.9KgPACKAGE SIZE625mm*300mm*100mmG.W4.8Kg?3.Product Feature and Application???Specific application scenarios:1.Data room: leakage, distribution, temperature and humidity, smoke, access control, UPS, air conditioning, power supply, etc.2. Distribution room: UPS, current, voltage, switching state, generator, battery, power supply, smoke detection, etc.3. Warehouse environment: such as grain, tobacco, medicine, chemical industry, food, etc., mainly for temperature and humidity, gas content, water quality, acidity and alkalinity, etc.4. Pipeline network nodes: gas, oil pipeline, railway, tunnel environment, etc.5.Enterprise workshop, shopping mall and other important areas: environment, fire control and other monitoring.4.Production Details??5.Product Usage DescriptionIt mainly monitors the parameters of three-phase voltage, phase current, line voltage, line current, active power, reactive power, frequency, power factor and the state monitoring of distribution switches. When some important parameters exceed the dangerous limit, the alarm will be given.UPS power supply (including DC power supply)Through the communication protocol and intelligent communication interface provided by UPS manufacturer, the operation status of UPS internal rectifier, inverter, battery, bypass, load and other components are monitored in real time. Once the components fail, the power environment monitoring system of the computer room will automatically alarm. In the system, UPS is monitored only and not controlled.Air-conditioning equipmentThrough real-time monitoring, the operation status and parameters of air conditioning components (such as compressors, fans, heaters, humidifiers, dehumidifiers, filters, etc.) can be comprehensively diagnosed, and the parameters of air conditioning settings (temperature, humidity, temperature upper and lower limits, humidity upper and lower limits, etc.) can be remotely modified through the management function of the engine room power environment monitoring system, as well as the precision air conditioning. Restart. Even if there are minor faults in the air conditioning unit, it can be detected by the power environment monitoring system in the room, and timely measures can be taken to prevent further damage to the air conditioning unit.Temperature and Humidity in Computer RoomIn each important position of the computer room, it is necessary to install a temperature and humidity detection module to record the temperature and humidity curve for the management staff to inquire. Once the temperature and humidity exceed the range, the alarm will be started immediately to remind the managers to adjust the working setting value of air conditioning or the equipment distribution in the room in time.Video surveillanceThe environment monitoring system of computer room integrates video monitoring. The image adopts MPEG4 video compression mode. It integrates multi-screen viewing, video playback, video teletransmission, trigger alarm, platform control and equipment linkage. The video system can also link with other input signals. Once the video alarms, it can also link with other equipment, such as dual-detector and gate magnet for video recording.Access ControlAccess control system is composed of controller, inductive card reader, electronic lock and door button (networking system plus communication converter). The card reading mode belongs to the non-contact card reading mode, and the system effectively monitors and manages the entry and exit personnel.?Lightning Protection SystemThe real-time monitoring of the lightning protection module is realized by the switch acquisition module. Usually, there are only two monitoring states: on-off and off.?Fire Control SystemThe monitoring of fire control system is mainly to collect fire alarm signal and gas spraying signal, but not to control fire control system.?6.Qualification and Service???Our service:?Timely: set up technical support department, open hotline service telephone, 7*24 hours technical support; provide close, timely and efficient service for customers.Professional: Professional support service engineers are equipped to provide professional support services to customers.Sincerity: User-oriented, set up the correct user service awareness of employees, and provide sincere service to users with good service attitude.Enthusiasm: technicians are enthusiastic, sincere and patient in solving user's problems and providing thoughtful service to users.?7.FAQ1.How many RS485 Sensors I can connect to the Monitoring Host ?4 RS485 Interface Port Supports Chain Connection, 255 sensors in total2.How many Relay Sensors I can connect to the Monitoring Host ?We would suggest not more than 16 sensors to keep the better operation3.Can I only buy the monitoring system only ?Yes, the monitoring system includes the hardware and software4.Does the software ChargeWe will charge for some integration protocol5.How do I know the Monitoring system can work with for my application ?We can offer the full solution and remote debugging if you need;?For precise air conditioning control, we will incorporate your protocol into?our system in advance.??8. Successful Application Project?Computer room monitoring system of an education bureau and its subordinate units in Changsha!?Monitoring Contents: Two UPS, two air conditioners, two distribution cabinets, 128 batteries, six temperature and humidity sensors, two leak detection modules, two access guards and eight video channels in the central computer room of the Education Bureau. The data set of 32 units under the headquarters is uploaded to the main room and accessed by a platform. Phone short message sound and light alarm after abnormal. http://www.anyingiot.com/data-c...bus-monitoring-host.html
Users browsing this topic
Guest
Forum Jump  
You cannot post new topics in this forum.
You cannot reply to topics in this forum.
You cannot delete your posts in this forum.
You cannot edit your posts in this forum.
You cannot create polls in this forum.
You cannot vote in polls in this forum.