logo
Welcome Guest! To enable all features please Login or Register.

Notification

Icon
Error

Login


Options
View
Go to last post Go to first unread
swpt_WFTU3cKx  
#1 Posted : Thursday, August 13, 2020 10:58:16 PM(UTC)
swpt_WFTU3cKx

Rank: Member

Groups: Registered
Joined: 8/12/2020(UTC)
Posts: 16

Features

The machine is applicable for aseptic filling and packing of liquid milk and non-soda drink, fruit juice, coffee, plant protein drink, tea beverage, fruit wine etc.

Specifications

  Item specification

Model PACK-V1-6000

Name aseptic filler

Capacity 6000 bags /H

Filling capacity 200 ml slim

Dimension 4500*2500*4200mm

Connect 2200 mm (W) × 3500 mm (H)

Weight 5000 kg

Electrical 380V±10 %( 3φ) 50/60Hz

Motor 35 kW

Air usage 500±100 L/ M( 0.6 ~ 0.7 Mpa)

Connect type and joint diameter: thread 1/2 4 pipes joint

Tap water usage 15 L/M( 0.3~0.45 Mpa、below 20℃ )

Connect type and joint diameter : thread 1/2 4 pipes joint

Steam usage: 4.5 kg/H(130 ± 5 ℃、0.17± 0.03 Mpa)

Connect type and joint diameter: DN25

H2O2 usage: 0.6~ 1.0 L/H( 30 ~ 50 %)

Control system: PLC(HM5)

Printing setting: without

Discharge conveyor: chain

Filling material temperature: 5℃~50℃

Filling density 150 CPD

Connect type and joint diameter supply: DN 38 SuS cape or thread

Return: DN 38 SuS cape or thread

Connect pressure: 50 ~ 150± 10 KPa

Container type:

Container specification: 106×41×63

Packing material type:

Packing material specification: 200S



II Main component

No.

Supplier

Name

Country of origin

1

MITSUBISHI

IPU

Japan

2

HITECH

Touch screen

Japan

3

Schneider

Electrical switch

France

4

GEMU

Control valve

Germany

5

SICK

Color sensor

Germany

6

ABB

Motor

Sweden

7

DANROL

Electrical roller

Demark

8

FESTO、 CAMOZZI

Controlling pneumatic part

Germany

9

SHINKO

Temperature Controller



Japan



III. Capability features:

1. High efficiency, low wastage

2. Easy operation

3. Stable moving

4. Precise filling



IV. Technical details

1. Pressure:

(1). Compressed air pressure: 0.6-0.7Mpa

(2). cooling water pressure: 0.3-0.45Mpa

(3). Hot water pressure: 0.3-0.45Mpa

(4). Steam pressure: 170-200Kpa

(5). Product pressure: 0.5-3.5bar

(6). Aseptic air pressure: 25-35Kpa

(7). Roller pressure: 0.3Mpa

(8).Short-stop vertical pressure: 2.0-2.5Kpa

(9). Vertical pressure: 2.5-4.0Kpa

(10).Photoelectric protect air pressure: 10-30Kpa

(11).Spray cup air pressure: 0.3Mpa

(12).Horizontal liquid pressure: 9.2-10.2Mpa

(13).Cutting pressure: 8.0-9.0Mpa

(14).Drawing correct cylinder pressure: 0.2-0.3Mpa

(15).Fold sealing pressure: 150-200Kpa

(16).Water pressure storage pressure: ≥0.5bar

(17). Adjusting valve I/P sensor pressure:

Pre-heating 0.1bar sterilize: 2.0bar

Clean 3.5bar produce: 0.8bar

(18).Aseptic room and H202 tank pressure: 20-35mmH2O –5-0mmH2O (1Mpa=1000Kpa=10bar)

2. Temperature:

(1). Hot water: 60-75℃(outside clean)

(2). Sterilize tank water pre-heating: 85℃

(3). Sterilize tank water: 80℃

(4).Sterilize tank H202: 74-76℃

(5).Air heater: 360℃

(6). Air heater pre-heating: 400℃

(7). Pipe sealing: 280℃

(8).Vertical seal: 380℃

(9). Air knife temperature: 125-130℃

(10).Pre-sterilize: 270 ℃ before produce, 120-135℃during produce.

(11).Steam temperature input: 120-140℃

(12).Inside sealing belt temperature: 190℃

(13).Air conditioner requirements: 28-35℃

(14).Paper seal temperature: 190-210℃

3. Flow

⑴.Left –right claw cooling water flow:≥0.7L/min

⑵. Constant current valve:3.8L/min

⑶.Product back flow :10%

⑷.Clean flow :≥8000L/h(2.2-3.5bar)

4. Others

(1).H2O2 :35%-50%

(2).Cleaning agent:0.8L-1L(outside clean)

(3). H2O2 :0.7-1.2L/h

⑷. Product temperature :5-50℃

⑸. Environment temperature:15-30℃

⑹. Lubricate oil:0.01L/h

⑺. Cooling water:10L/min

⑻. Max granule:600μm(horizontal)

⑼. Steam flow:2.4Kg/h

(10).H2O2 PH value:2-4 http://www.luwico.com
Users browsing this topic
Guest (2)
Forum Jump  
You cannot post new topics in this forum.
You cannot reply to topics in this forum.
You cannot delete your posts in this forum.
You cannot edit your posts in this forum.
You cannot create polls in this forum.
You cannot vote in polls in this forum.